Data centers
Three locations,two countries, one point of contact
Your servers run in professional data centers in the Frankfurt area and in the Netherlands. Here you can see what each site offers in terms of power, cooling, security and connectivity.
Ourlocations at a glance
Two data centers in the Rhine-Main area and one in South Limburg, right at the German border. All three are located in the European Union.

Frankfurt am Main · Germany
firstcolo FRA4
- ISO 27001
- TÜV level 3
- 100% green power

Offenbach am Main (Frankfurt area) · Germany
maincubes FRA01
- 2N power
- 6 MW IT capacity
- PUE ≤ 1.3

Eygelshoven · Netherlands
SkyLink NL
- 1,500 m²
- A and B feeds
- Fiber to AMS and FRA
Frankfurt am Main · Germany
firstcolo FRA4in the Frankfurt Werkhaus
The Werkhaus on Kruppstraße is a firstcolo data center in Frankfurt am Main, close to the DE-CIX internet exchange. Power and air conditioning are redundant, and a team is on site around the clock.
Facilities
- Location
- Kruppstraße 105, 60388 Frankfurt am Main, Germany
- Area
- About 1,200 m² of technical space with room for around 1,000 racks
- Power
- Redundant UPS systems, two standby power systems with a diesel generator, separate sub-distributions and surge protection; 16 A and 32 A circuits at 230 V and 400 V
- Cooling
- Precision air conditioning with N+1 redundancy, contained hot and cold aisles, direct and indirect free cooling
- Access and security
- Biometric access control, video surveillance and an on-site team around the clock
- Fire protection
- Aspirating smoke detection (VESDA) for early warning, argon gas extinguishing, F90 walls with steel doors and automatic fire brigade alerting
- Connectivity
- Carrier-neutral, connections to nearly all carriers based in Frankfurt possible, close to DE-CIX; according to PeeringDB six internet exchanges are present on site, including KleyReX and LOCIX
- Certifications
- ISO/IEC 27001:2022, ISO 9001:2015, TÜV-certified data center level 3
- Energy and efficiency
- 100% green power for the colocation infrastructure, PUE below 1.3 according to the operator
Offenbach am Main · Germany
maincubes FRA01in Offenbach, right outside Frankfurt
FRA01 is located in Offenbach am Main on the campus of the local energy utility and is marketed by the operator as a Frankfurt site. The building was planned as a data center from the ground up, built in 2017 and received the German Data Center Award for its architecture.
Facilities
- Location
- Goethering 29, 63067 Offenbach am Main, Germany (Rhine-Main area, Frankfurt region)
- Area
- 4,200 m² of IT space on three levels, each with two IT rooms of 700 m²
- Power
- 2N redundant power supply via a ring system, 6 MW IT capacity, 1 MW of power and cooling capacity per IT room, up to 40 kW per rack
- Cooling
- Kyoto cooling with outside air in N+1 redundancy, consistent cold aisle concept
- Access and security
- Multi-level access control with vein scanners, video surveillance and a round-the-clock security service operating from a bulletproof room
- Fire protection
- Early fire detection and an automatic gas extinguishing system
- Connectivity
- Carrier-neutral with currently 19 network operators and platforms on site, DE-CIX enabled site, redundant supply via cross-connects
- Certifications
- ISO/IEC 27001, ISO 9001, ISO 14001, ISO 50001, EMAS, ISAE 3402 (SOC 1) and SOC 2, TÜV Saarland per DIN EN 50600 availability class 3
- Energy and efficiency
- Green power from renewable sources, guaranteed PUE of 1.3 or lower, energy management per ISO 50001
Eygelshoven · Netherlands
SkyLink NLat the German-Dutch border
The SkyLink data center is located in Eygelshoven in South Limburg, about 200 meters from the German border, between the internet exchanges in Frankfurt and Amsterdam. The operator owns the building.
Facilities
- Location
- Bart van Slobbestraat 16B, 6471 WV Eygelshoven, Netherlands
- Area
- Currently about 1,500 m²
- Power
- Transformers with 2 × 1,750 kVA, 1 × 1,000 kVA and 1 × 630 kVA in a ring circuit, supplied from separate substations, one A and one B feed with 16 A per rack, UPS with 2 × 200 kW for premium racks
- Cooling
- 2.2 MW cooling capacity, nine recirculating air conditioning units on redundant cooling circuits, cold aisle containment
- Access and security
- Multi-level building access, keycard entry, round-the-clock video surveillance with motion detection and at least three months of retention
- Fire protection
- Smoke detectors in the raised floor
- Connectivity
- Carrier-neutral, direct fiber routes to Amsterdam and Frankfurt am Main, SN-IX internet exchange on site
- Certifications
- Designed to Tier 3 standard according to the operator, no published certificate
- Energy and efficiency
- Power mix and PUE on request
The operator states a design to Tier 3 standard but has not published a certificate for this site. Information on the power mix and PUE is available from us on request.
The three locationscompared
The key facts side by side. The values come from the data center operators and from public directories such as PeeringDB.
| Feature | firstcolo FRA4 | maincubes FRA01 | SkyLink NL |
|---|---|---|---|
| Location | Frankfurt am Main, Germany | Offenbach am Main (Frankfurt area), Germany | Eygelshoven, Netherlands |
| Area | about 1,200 m² technical space, approx. 1,000 racks | 4,200 m² IT space, 6 MW IT capacity | about 1,500 m² |
| Power | redundant UPS, two standby power systems with diesel generator | 2N via ring system, 1 MW per IT room | A and B feed per rack, UPS for premium racks |
| Cooling | N+1 redundant, free cooling | Kyoto cooling with outside air, N+1 | 2.2 MW, redundant cooling circuits |
| Fire protection | VESDA, argon extinguishing | early detection, gas extinguishing | smoke detectors in the raised floor |
| Access and security | biometrics, video, team around the clock | vein scanners, video, security service around the clock | keycard, video around the clock |
| Connectivity | carrier-neutral, close to DE-CIX, six internet exchanges | carrier-neutral, 19 network operators, DE-CIX enabled | carrier-neutral, fiber to AMS and FRA, SN-IX |
| Certifications | ISO 27001, ISO 9001, TÜV level 3 | ISO 27001, 9001, 14001, 50001, SOC 1/2, TÜV class 3 | Tier 3 design per operator, no certificate |
| Energy and efficiency | 100% green power, PUE below 1.3 | green power, PUE ≤ 1.3, ISO 50001 | on request |
firstcolo FRA4
- Location
- Frankfurt am Main, Germany
- Area
- about 1,200 m² technical space, approx. 1,000 racks
- Power
- redundant UPS, two standby power systems with diesel generator
- Cooling
- N+1 redundant, free cooling
- Fire protection
- VESDA, argon extinguishing
- Access and security
- biometrics, video, team around the clock
- Connectivity
- carrier-neutral, close to DE-CIX, six internet exchanges
- Certifications
- ISO 27001, ISO 9001, TÜV level 3
- Energy and efficiency
- 100% green power, PUE below 1.3
maincubes FRA01
- Location
- Offenbach am Main (Frankfurt area), Germany
- Area
- 4,200 m² IT space, 6 MW IT capacity
- Power
- 2N via ring system, 1 MW per IT room
- Cooling
- Kyoto cooling with outside air, N+1
- Fire protection
- early detection, gas extinguishing
- Access and security
- vein scanners, video, security service around the clock
- Connectivity
- carrier-neutral, 19 network operators, DE-CIX enabled
- Certifications
- ISO 27001, 9001, 14001, 50001, SOC 1/2, TÜV class 3
- Energy and efficiency
- green power, PUE ≤ 1.3, ISO 50001
SkyLink NL
- Location
- Eygelshoven, Netherlands
- Area
- about 1,500 m²
- Power
- A and B feed per rack, UPS for premium racks
- Cooling
- 2.2 MW, redundant cooling circuits
- Fire protection
- smoke detectors in the raised floor
- Access and security
- keycard, video around the clock
- Connectivity
- carrier-neutral, fiber to AMS and FRA, SN-IX
- Certifications
- Tier 3 design per operator, no certificate
- Energy and efficiency
- on request
Find the right locationfor your project
Configure your server or tell us what you need in terms of location and connectivity.
Frequently asked questions about our data centers
Technical details about our servers and the API can be found in the documentation.